TWELVE CHANNEL ECG RECODER BPL Cardiart 9108 D 12 CHANNEL
Twelve Channel ECG Recording
Simultaneous 12 channel ECG recording with 12 lead simultaneous acquisition
High Resolution Display
7 inch high resolution display enables the easy viewing of patient demographics and real time
ECG data (optional touch screen)
ECG Analysis and Interpretation
Gender, age & race specific advanced ECG analysis & interpretation – The Glasgow ECG Interpretation
Algorithm
QWERTY Alphanumeric Keyboard
Ensures the freedom of easy use
Ease of Operation
The user-friendly design of the machine ensures easy operation
External Archiving
Supports external archiving devices such as USB drive, SD card for virtually unlimited ECG data
Storage
File Formats
Standard PDF and Optional SCP, XML DICOM Formats
Thermal Recorder
Built-in high resolution thermal recorder
Internal Memory
Has an Internal Memory, which can store up to 800 ECG recordings
Built-in Rechargeable Battery
High performance Li-ion rechargeable battery enables mains independent operations
PC Interface
Interfaces with PC using optional Smart-View software
Pace maker detection
This feature ensures recognition of pacing signal artifacts
Trolley
Custom trolley available as an option
GENERAL SPECIFICATIONS
Display 7 inches, 800×480 TFT LCD Screen
Touch Screen 7 inches, optional
PHYSICAL SPECIFICATIONS
Dimensions (Main Unit) 361mmx262mmx135mm
(14.2inx10.3inx5.3in); ±2mm
Weight (Main Unit) 4.2kg (9.3 lbs) (Excluding recorder paper and battery)
PERFORMANCE SPECIFICATIONS
Recording
Recorder Thermal dot-matrix recorder
Printing Density 8 dots per mm / 200 dots per inch (amplitude axes)
40 dots per mm / 1000 dots per inch (time axes @ 25mm/s)
Recorder Paper Folded Thermal Paper:
210 mm x 140 mm x 144 pages
210 mm x 295 mm x 100 pages (optional)
215 mm x 280 mm x 100 pages (optional)
Effective Width 210 m m
Paper Speed 5mm/s, 6.25mm/s, 10mm/s, 12.5mm/s, 25mm/s, 50mm/s (±3%)
HR Recognition
HR Range 30 BPM – 300 BPM
Accuracy ±3 BPM
ECG Unit
HR Range 30 BPM – 300 BPM
Accuracy ±3 BPM
Leads 12 standard leads
Acquisition Mode Simultaneously 12 leads
A/D 24Bits
Frequency Response 0.01Hz – 300Hz
Gain 1.25, 2.5, 5, 10, 20, 10/5, AGC (mm/mV)
Input Impedance ≥100MQ (10Hz)
Filter AC Filter: 50Hz/60Hz/Off
DFT Filter: 0.01Hz/0.05Hz/ 0.15Hz/0.25Hz/ 0.32Hz/ 0.5Hz/0.67Hz
EMG Filter: 25Hz/35Hz/45Hz/Off
LOWPASS Filter: 150Hz/100Hz/75Hz\
CMRR ≥140dB (AC Filter is On)
≥123dB (AC Filter is Off)
Sampling Frequency 16,000 Hz
Pacemaker Detection Available
SAFETY SPECIFICATIONS
Comply with IEC 60601-1:2005
IEC 60601-1:2007
EN 60601-1:2006
IEC/EN 60601-2-25
EN 60601-1-2:2007
Anti-electric-shock type Class I with internal power supply
Anti-electric-shock degree CE type with defibrillator-proof
Degree of protection against
harmful Ingress of water Ordinary equipment (sealed equipment without liquid proof)
Working Mode Continuous Operation
ENVIRONMENT SPECIFICATIONS
Transport & Storage Working
Temperature -20ºC (-4ºF) ~ ±5ºC (+41 F) ±40ºC
+55ºC (+131ºF) (+104 F)
Relative Humidity 25%-93% Non-Condensing 25%-80% Non-Condensing
Atmospheric Pressure 70 kPa ~106kpa
under Transport
& Storage and
Working: 86 KPa
~106 KPa
POWER SUPPLY SPECIFICATIONS
Recorder Thermal dot-matrix recorder
Mains Supply Operating Voltage: 100V-240V AC
Operating Frequency: 50Hz/60Hz
Input Current: 0.9-0.4A
Battery Specifications Battery Type: Rechargeable Lithium Ion
Rated Voltage: 14.8V
Rated Capacity: 2500mAh
4 hours with fully charged battery or 300
continuous ECGs print