TWELVE CHANNEL ECG RECODER BPL Cardiart 9108 D 12 CHANNEL

Product Code: AVI-1505 Category:

Twelve Channel ECG Recording 

Simultaneous 12 channel ECG recording with 12 lead simultaneous acquisition

High Resolution Display

7 inch high resolution display enables the easy viewing of patient demographics and real time

ECG data (optional touch screen) 

ECG Analysis and Interpretation 

Gender, age & race specific advanced ECG analysis & interpretation – The Glasgow ECG Interpretation

Algorithm 

QWERTY Alphanumeric Keyboard 

Ensures the freedom of easy use 

Ease of Operation 

The user-friendly design of the machine ensures easy operation 

External Archiving 

Supports external archiving devices such as USB drive, SD card for virtually unlimited ECG data

Storage 

File Formats

Standard PDF and Optional SCP, XML DICOM Formats 

Thermal Recorder 

Built-in high resolution thermal recorder 

Internal Memory 

Has an Internal Memory, which can store up to 800 ECG recordings 

Built-in Rechargeable Battery 

High performance Li-ion rechargeable battery enables mains independent operations 

PC Interface

Interfaces with PC using optional Smart-View software 

Pace maker detection 

This feature ensures recognition of pacing signal artifacts 

Trolley 

Custom trolley available as an option 

GENERAL SPECIFICATIONS 

Display                                     7 inches, 800×480 TFT LCD Screen

Touch Screen                            7 inches, optional 

PHYSICAL SPECIFICATIONS

Dimensions (Main Unit)              361mmx262mmx135mm

(14.2inx10.3inx5.3in); ±2mm

Weight (Main Unit)                     4.2kg (9.3 lbs) (Excluding recorder paper and battery)

PERFORMANCE SPECIFICATIONS 

Recording 

Recorder                                   Thermal dot-matrix recorder

Printing Density                         8 dots per mm / 200 dots per inch (amplitude axes)

40 dots per mm / 1000 dots per inch (time axes @ 25mm/s)

Recorder Paper                         Folded Thermal Paper:

210 mm x 140 mm x 144 pages

210 mm x 295 mm x 100 pages (optional)

215 mm x 280 mm x 100 pages (optional)

Effective Width                                     210 m m

Paper Speed                             5mm/s, 6.25mm/s, 10mm/s, 12.5mm/s, 25mm/s, 50mm/s (±3%) 

HR Recognition 

HR Range                                 30 BPM – 300 BPM

Accuracy                                  ±3 BPM 

ECG Unit

HR Range                                 30 BPM – 300 BPM

Accuracy                                  ±3 BPM

Leads                                       12 standard leads

Acquisition Mode                      Simultaneously 12 leads

A/D                                          24Bits

Frequency Response                 0.01Hz – 300Hz

Gain                                         1.25, 2.5, 5, 10, 20, 10/5, AGC (mm/mV)

Input Impedance                        ≥100MQ (10Hz)

Filter                                         AC Filter: 50Hz/60Hz/Off

DFT Filter: 0.01Hz/0.05Hz/ 0.15Hz/0.25Hz/ 0.32Hz/ 0.5Hz/0.67Hz

EMG Filter: 25Hz/35Hz/45Hz/Off

LOWPASS Filter: 150Hz/100Hz/75Hz\

CMRR                                       ≥140dB (AC Filter is On)

≥123dB (AC Filter is Off)

Sampling Frequency                  16,000 Hz

Pacemaker Detection                Available 

SAFETY SPECIFICATIONS

Comply with                              IEC 60601-1:2005

IEC 60601-1:2007

EN 60601-1:2006

IEC/EN 60601-2-25

EN 60601-1-2:2007

Anti-electric-shock type             Class I with internal power supply

Anti-electric-shock degree          CE type with defibrillator-proof

Degree of protection against

harmful Ingress of water            Ordinary equipment (sealed equipment without liquid proof)

Working Mode                          Continuous Operation 

ENVIRONMENT SPECIFICATIONS

Transport & Storage                  Working

Temperature                              -20ºC (-4ºF) ~                            ±5ºC (+41 F) ±40ºC

+55ºC (+131ºF)                          (+104 F)

Relative Humidity                      25%-93% Non-Condensing        25%-80% Non-Condensing

Atmospheric Pressure               70 kPa ~106kpa

under Transport

& Storage and

Working: 86 KPa

~106 KPa 

POWER SUPPLY SPECIFICATIONS

Recorder                                   Thermal dot-matrix recorder

Mains Supply                            Operating Voltage: 100V-240V AC

Operating Frequency: 50Hz/60Hz

Input Current: 0.9-0.4A

Battery Specifications               Battery Type: Rechargeable Lithium Ion

Rated Voltage: 14.8V

Rated Capacity: 2500mAh

4 hours with fully charged battery or 300

continuous ECGs print