MONOPHASIC DEFIBRILLATOR DF 2509/R
LCD Display with Backlight
5.7” Monochrome LCD display with backlight delivers crisp and accurate readings with better contrast and
Brightness
Charging Time
Takes less than 5 seconds to charge to 360J with a fully charged new battery
Event Recording
Stores and prints pre & post event data up to 24 events
Thermal Printing
Allows the printing of saved events using a highresolution thermal printer
Visual and Audible Charge Indicator
It provides visual and audible high voltage charge done indication
Enhanced Battery Usage
It delivers more than 100 shocks of 360J with fully charged new battery
Optional
DF 2509 R comes with printer
Product Specifications
Technical Specification
Power Supply 100-240 V AC; 50/60 Hz
Power Consumption <100VA
Battery Type Rechargeable Sealed Lead Acid battery
Battery Capacity 12V, 4.5AH; 100 discharges of 360 joules or 7 hrs of monitoring with
fully charged new battery
Dimensions 260 (W) X 280 (D) X 250 (H) mm
Weight 10.5 kgs (with battery & paddle)
Environment Operating temparature: 0⁰ C to 400 C
Relative humidity: 15 to 95% RH non condensing
Defibrillator
Waveform 5 milliseconds Monophasic Lown Pulse
Energy Select with External Paddles 2-360J in steps of 2,3,5,7,10,20,30, 50, 70, 100, 150, 200, 300, 360
Energy Select with Internal Paddles 2-50J in steps of 2, 3, 5, 7, 10, 20, 30, 50
Charge Time < 5 secs to 360 J with battery (fully charged new battery)
< 15 secs to 360 J without battery (AC mains only)
Charge Indicator Charge ready LED on the Front Panel & audible tone
Charge ready LED on Apex Paddle
Available & Delivered Energy Displayed on the screen
Synchronization Defibrillation synchronized to the R wave Marker indication on ECG waveform
Sync Mode Indication Message on monitor screen and LED indication on front panel
Paddles Integrated adult and paediatric paddles
Product Specifications
Monitor
Display 5.7 inch STN LCD Display
ECG Input Modes ECG input through paddles or 3 Lead Patient cable (
Lead I,II and III)
Leads Off Message On Screen Message with alert tone
CMRR > 90 dB @ 50 Hz
Input Impedance > 2.5M Ohm
Frequency Response 0.5 to 35 Hz
Sweep Speed 25 ± 1 mm/Sec
Display Time 5 secs.
HR Display & Accuracy 10-300 bpm
±2 Bpm or ±2%, whichever is higher
1mV Cal Signal Vertical bar indication (varies withgain)
ECG Out 1V/mV(depends on gain setting)
Defibrillator Protection A v a i l a b l e
Printer (Optional)
Recording Type Thermal Array recording
Paper Size 50 mm X 20 mts; Print width; 40Mm
Paper Speed 25 ± 1 mm/Sec
Recorder Mode Configurable to print either realtime or 6 seconds delayed ECG
Event Recording Stores and prints 3 seconds ofpre critical data and 7 seconds post critical event data up to 24 events.
Print Annotates Time, Date, HR, HR limits, Event marker, ECG input source, ECG gain, Defibrillator mode, Selected and Delivered energy, Patient Impedance, Peak current and
Hospital name.
Standard Accessories
Defibrillator Paddles (Adult & Paediatric) 1 no.
Disposable Electodes 30 nos.
Patient Cable (3 Lead) 1 no.
Mains Cable (Power Cord) 1 no.
Cardijelly 1 bottle
Earth Cable 1 no.
Accessory Bag 1 no.
User Manual 1 no.
Recording Paper 1 roll – 20 mtrs.