BISPHASIC DEFIBRILLATOR ABM DF-11

Product Code: AVI-1536 Category:

FEATURES:

  • 7″ Colour Display with built in printer
  • Charging time 6 sec on mains
  • Offers variable energy level selection

(2,3,5,10,20,30,50, 70, 100, 150,200 Joules)

  • Battery capacity 70-100 shocks on single charge
  • Adult & paediatric paddles support
  • Compact & Light weight
  • Print out on 2″ thermal paper
  • Voice prompt facility

 

OPTIONAL   :

AED, Pacer, Sp02, NIBP, EtC02,

Internal Paddle, 360 Joules

 

GENERAL

 

Display 7 Inch   Colour TFT

 

 

Display Area

 

150 mm x 90 mm
Dimensions H 280  x W 330  x D 220  mm  (Max)  without   Paddle
Weight Approx.  6 Kgs. Max.
Unit ON-OFF By front  panel  push  bunon
Operation By front panel  keyboard, Encoder
Alarm User adjustable   high & low limit. Audible  and visual

alarming

Trend 24 hrs graphical   and tabular  trend  of ECG,Sp02, NIBP,EtC02
Charge/ Discharge Charge and Shock  buttons  on front  panel  and  Control paddles

POWER SUPPLY 

Input                             150-270 VAC, 50  Hz 10

Battery                           12 V 4.5Ah, Rechargeable

Battery capacity               3 hours for monitor and 70-100 shocks on full charge

LED indicator                  Low battery and battery charging

Power consumption         30 Watts (max) in ECG mode

ENVIRONMENTAL 

Operating Temp              +5°C to +5°C

Humidity             up to 95% non-condensing

Defib (External Paddles)

Operating Mode                        Manual

Waveform                                  Biphasic Truncated Exponential

Energy                                      2 to 200 joules in 12 steps selection

Energy display                           Displays selected and charged/delivered   energy Energy delivery begins within 60 ms of the ORS Peak

Charging Time                            6 seconds on Mains

Paddle Assembly                            External paddle assembly with coil retractable    high voltage cable. Adults & Pediatric paddle integrated to same handle

Check Mode                              Manual check mode

Patient Impedance range           35 ohm to 250 ohm

Shock Delivery                           Through paddles or pads

Defib (Internal Paddles) (Optional) 

Operating Mode                                    Manual

Waveform                                  Biphasic Truncated Exponential

Energy                                       2 to 50 joules in 8 steps selection

Synchronous Cardio                  Energy delivery begins within 60 ms of

Version                                      the ORS Peak

Charging Time                            6 seconds on Mains

Paddle Assembly             Internal paddle assembly with paddle extension cord

ECG

 Frequency response               0.5 Hz to 35 Hz

Patient isolation                          Optical isolation

Lead selection                            Lead I,  II  and Ill

Gain setting CMRR                        0.5,  1.0  and 2.0

Sweep speed                              12.5, 25.0, 50.0 mm/sec

Digital filter                                 Digital signal  processing  for good quality  of ECG

ECG traces viewing                       4 seconds of ECG traces

HEART  RATE

Range                                         10-250  BPM

Accuracy                                    +/ 2 BPM

Resolution                                     1    BPM

Tone                                          Beep on every  ORS detected

Alarm  limit setting             10-250  (step of 1)

PRINTER 

Paper Type                                    Thermal  paper 50/55mm   width,  20 meters  length for 2 inch  printer

Event  Printing                                 Prints  5 seconds  pre  & post ECG with  Date, Time Energy and  mode.Shock  Status

ECG  in  Defitl Mode                           Prints  last 10  sec  ECG through   paddle

Print  Annotates  in                            Time,  Date,  Mode,  lead name,  gain,  sweep speedDefib Mode

ECG  in  Monitor                                Prints  last 10  sec  ECG through   cable

Mode                                          Print Annotates   in Time,Date,selected    lea name,  Gain Sweep speed

Monitor  Mode                                Prints the status of Shock,  Energy,  Date and Time Mode

Manual   Defit>  Check

Sp02 (Optional) 

Systolic,Diastolic    and Mean  arterial  pressure

Range                                         0 -100%Accuracy:70    -100%   +  2digits,50  – 69% +  3 digits

Pulse  rate                                 Displayed  in  ECG  window,  when PR is selected

Pulse  beep                                    Yes,  with volume control

PR  range                                   :    10  to 250 bpm  ( +/-2bpm)

Pitch  variation  with  change   in oxygen   saturation

NIBP (Optional) 

Systolic,Diastolic  and Mean  arterial pressure

Method                                        Oscillometric

NIBP  interval                        User selectable  – 2 min. to 25min.

Modes                                         Manual,  auto

Cuff  deflation                                Automatic

Safety features                    Automatic deflation if cuff pressure exceeds 280mmHg

NIBP  status display               “Ready”,  when  not taking  reading as “Measuring”,   when taking  reading  and “Error, if

reading could  not be taken due to some error while measuring

Patient Type                                Adult,  Pediatric,   Neonate

AED Mode (Optional) 

PACER (Optional) 

Wave form                                   Mon aphasic

Modes                                        Demand  or Non  Demand

Pulse  Current                                 From  1 OmA to 150  mA ( resolution  of 1 O  mA),

Pulse  Duration                                40 ms (+/-1ms)

Pacing  rate                                   From  20 ppm to 250  ppm (increments  of 1   ppm)

Refractory period                              340ms  (from30  to80ppm);240ms(from90   to180ppm)

Maximumoutput                               150  voltage

Impedance   range                           200 ohm to 1 k ohm

EtC02 (Optional)

Parameter                         EtC02,RR

Adaptor                                        Adult, Pediatric, Neonate

Measurement    Mode                         Mainstream  & side stream

EtC02  Range                                  0-100mmhg

Accuracy                                                    +!- 2 mmHg

Respiration   Range                                    0-120 bpm