ECG MACHINE SINGLE CHANNEL BPL CARDIART 108T DIGI
BPL Cardiart 108T-DIGI
· High Fidelity Thermal Array Recording · Sharp and Clear Trace · Electronic Lead Selection · Easy operation · AC Mains/Built-in Rechargeable Battery operation
TECHNICAL SPECIFICATIONS
|
POWER SUPPLY
• |
Power supply
Power consumption Battery Battery charging indicator Battery low indication Recharging time Mains protection Battery protection Auto shutdown |
230 V ± 10%: 50 Hz
Less than 6 VA Internal rechargeable NiMH: 9.6 V 1500 mAH Yes Yes Approximately 14 Hours 100% Fues: T 0.1 A Polymer resettable fuse Yes |
RECORDING | Thermal paper
Recording system Print Width Print channel Paper transport speed |
In rolls: Width 50 mm, Length 20 mts, gridded
Thermal printer, 8 dots/mm 40 mm 1 26 or 50 mm / sec.
|
SENSITIVITY | Input Dynamics Input impedance Frequency Response Time constant CMRR
DF protection |
± 300 mV @ 0 Hz: ± 5 mV in the pass band
> 100 M ohms. 0.1 Hz to 150 Hz (-3 dB) without Mains / Muscle Filter 1.6 seconds Greater than 90 dB @ 50 Hz Internal |
STANDARD Patient Cable 1 no. Earth Cable 1 no.
ACCESSORIES Clipon Electrodes 4 nos. Chest Electrode with Rubber Bulb 1 no.
Accessory Case 1 no. Cardi-Jelly Bottle 1 no.
Recording Paper (20 m roll) 1 no. Instruction Manual 1 no.
12 bits: 800 samples/sec.
Real time acquisition and printing of selected lead
Lead I, II, Ill, aVR, aVL, aVF or V
5, 1C, or 20 mm/mV ± 5%
Digital linear phase Mains interference cum muscle
tremor filter (22 Hz – 3 dB)
Rubber keypad with 7 function keys and 15 LED function
indicators
Single Channel ECG Recording
Enables the recording of all leads Sequentially
Lead off Indication
Notifies when one or more ECG electrodes are not properly affixed to a patient
Electronic Lead Selection
Enables the easy selection of requisite leads for measurements
Auto Power Off
Preserves the battery charge and activates automatically when not in use
Real Time High Fidelity Thermal Array Recording
Enables the user to acquire accurate and quality recording
Built-in Rechargeable Battery
Notifies when one or more ECG electrodes are not properly affixed to a patient
Electronic Lead Selection
Enables the easy selection of requisite leads for measurements
Auto Power Off
Preserves the battery charge and activates automatically when not in use
Real Time High Fidelity Thermal Array Recording
Enables the user to acquire accurate and quality recording
Built-in Rechargeable Battery
Defibrillation Voltage Protection
The machine is protected from defibrillators high voltage when used
Ease of Operation
The user-friendly design of the machine ensures easy operation