ECG MACHINE SINGLE CHANNEL BPL CARDIART 108T DIGI

Product Code: AVI-1501 Category:
BPL Cardiart 108T-DIGI

·      High Fidelity Thermal Array Recording

·      Sharp and Clear Trace

·      Electronic Lead Selection

·      Easy operation

·      AC Mains/Built-in Rechargeable Battery operation

TECHNICAL SPECIFICATIONS

 

GENERAL Dime;ision (Ind Handle) Weight

ENVIRONMENTAL Operating Temperature Relative Humidity Storage Temperature Relative Humidity

STANDARDS
Safety Standard

EMC

325 mm (L) x 210 mm (W) x 90 mm (H)
< 2.6 Kgs.10 to 40 deg. C.25 to 95% non condensing

-10 to 50 deg. C.

10 to 95% non condensing

Compliance to Class 1, CF type equipment
IEC-60601-1 & 60601-2-25 Standards
EG-60601-1-2

POWER SUPPLY

Power supply

Power consumption

Battery

Battery charging indicator

Battery low indication

Recharging time

Mains protection

Battery protection

Auto shutdown

230 V ± 10%: 50 Hz

Less than 6 VA

Internal rechargeable NiMH: 9.6 V 1500 mAH

Yes

Yes

Approximately 14 Hours 100%

Fues: T 0.1 A

Polymer resettable fuse

Yes

RECORDING Thermal paper

Recording system

Print Width

Print channel

Paper transport speed

In rolls: Width 50 mm, Length 20 mts, gridded

Thermal printer, 8 dots/mm

40 mm

1

26 or 50 mm / sec.

 

SENSITIVITY Input Dynamics Input impedance Frequency Response Time constant CMRR

DF protection

± 300 mV @ 0 Hz: ± 5 mV in the pass band

> 100 M ohms.

0.1 Hz to 150 Hz (-3 dB) without Mains / Muscle Filter

1.6 seconds

Greater than 90 dB @ 50 Hz

Internal

STANDARD                      Patient Cable                                             1 no.          Earth Cable                                                        1 no.

ACCESSORIES                 Clipon Electrodes                                    4 nos.        Chest Electrode with Rubber Bulb                1 no.

Accessory Case                                        1 no.          Cardi-Jelly Bottle                                              1 no.

Recording Paper (20 m roll)                 1 no.          Instruction Manual                                          1 no.

 

12 bits: 800 samples/sec.

Real time acquisition and printing of selected lead

Lead I, II, Ill, aVR, aVL, aVF or V

5, 1C, or 20 mm/mV ± 5%

Digital linear phase Mains interference cum muscle

tremor filter (22 Hz – 3 dB)

Rubber keypad with 7 function keys and 15 LED function

indicators

Single Channel ECG Recording

Enables the recording of all leads Sequentially

Lead off Indication

Notifies when one or more ECG electrodes are not properly affixed to a patient

Electronic Lead Selection

Enables the easy selection of requisite leads for measurements

Auto Power Off

Preserves the battery charge and activates automatically when not in use 

Real Time High Fidelity Thermal Array Recording

Enables the user to acquire accurate and quality recording

Built-in Rechargeable Battery

Notifies when one or more ECG electrodes are not properly affixed to a patient

Electronic Lead Selection

Enables the easy selection of requisite leads for measurements

Auto Power Off

Preserves the battery charge and activates automatically when not in use 

Real Time High Fidelity Thermal Array Recording

Enables the user to acquire accurate and quality recording

Built-in Rechargeable Battery

Defibrillation Voltage Protection

The machine is protected from defibrillators high voltage when used

Ease of Operation

The user-friendly design of the machine ensures easy operation