It is state-of-the-art breast cancer detection system that is designed to improve the quality & comfort of mammograms.The system produces high quality images that allow for better visualization of breast tissue, aiding the early detection of breast cancer.This advance system also includes features that reduce procedure times & improve patient comfort.It delivers high quality breast images-consistently, efficiently & easily.
Groundbreaking Technology
Image quality – clearly excellent
It is state-of-the-art breast cancer detection system that is designed to improve the quality & comfort of mammograms.The system produces high quality images that allow for better visualization of breast tissue, aiding the early detection of breast cancer.This advance system also includes features that reduce procedure times & improve patient comfort.It delivers high quality breast images-consistently, efficiently & easily.
Groundbreaking Technology
Easy to Use
The A.S.T. paddle [optional accessory] assures more uniform compression across the entire breast & improve immobilization of breast tissue, resulting in reduce mobile artifacts & superior image quality.Paddle prevents over-compression at the chest wall by showing pressure numeral therefore maximizing patient comfort.The integrity exposure film 4 mm deeterbreast tissue is visualized.Multi-mammograms in one fil…
Technical Specification
High Frequency [40 Khz] Mammography Unit
Generator | Rotating Anode |
X-ray Generator | 4.5 KW high frequency |
KV output | 20KV to 39 KV [1 KV steps] |
mAs Output | 1mAs to 650 mAs |
X-ray tube | Rotating Anode Xray tube |
Focal Spot | Small Focus = 0.1 mm |
Large Focus = 0.3 mm | |
Target Material | Molybdenum |
Target Angle | 12.5º |
Tube Angel | 0 to 9 variable |
Anode Rotation | Anode turn 9700 rpm |
Anode Hea: | |
Storage capacity | 225 KJ [300KHU] |
Inherent Filtrations | Be-0.05 mm |
Control Panel | Micro Processor controlled Feather Touch control panel |
Technique Selection | Manual two point Technique [KV, mAs] |
Display | KV/mAs [LCD Screen Display] |
switches | Focal spot selection machine on/off x-ray “ON” |
Stand Assembly U Arm Movement | Switches for up/down movement of ‘U’ armed placed. Conveniently on both sides of ‘U’ Arm |
Vertical Movement | 600 mm – 1050 mm [motor operated] |
Angular Movement | + 180º X-ray tube |
Focus Film Distance | SID 650 mm [65cms] |
Breast Compression | Motorized controlled compression system |
A.S.T paddles | Compression paddles for normal & magnifications model [spot compression. Compression scale: 0 to 10 cm |
Cone | Cone for localization & Radiation protection |
Magnification Device | 1.5 times [optional feature] |
Bucky | 180×240 mm motor operated bucky grid [optional feature] |
Cassette size | 180×240 mm [choose optional sizes] |
Collimator | Light beam collimator with auto shut off [optional features] |
A.E.C` | Automatic exposure control [optional feature] |
Exposure switch hand switch with retractable cord | |
Power Supply | Single phase, 5 KVA 230 volts + 10%, [110V] AC 50 Hz/60 Hz |
15 Amps with independent earthling | |
Biopsy attachment optional |