HemoCue® Albumin 201 System

Product Code: AVI-656 Category:

The Easy Way to Reliable Early Detection

 

Fast, portable and easy to use, the HemoCue® Albumin 201 System is ideal within diabetes care, hypertension treatment and as a possible marker for preeclampsia during pregnancy. The HemoCue® Albumin 201 System is an easy, lab-accurate means of identifying microal buminuria – long before any possible symptoms of renal or vascular complications may appear. HemoCue’s patented microcuvette technology enables quantitative test results right at the point of care. You can make immediate treatment decisions, and give direct feedback to the patient.

Certainty in Vital Decisions

  • Lab-accurate results for screening, diagnosis and monitoring
    • Ability to monitor changes in albumin concentration in the very low range (5-20 mg/L)
    • Detection of low concentrations enables early treatment to delay the onset of future microvascular complications
  • Fast Results With Ease
    • Ease of use with minimal training – Three simple steps
    • Test results in just 90 seconds
    • No need for lab confirmation due to quantitative results

    Trusted and Accepted Methodology

    • Built on HemoCue’s proven microcuvette technology
    • Factory calibrated system, ensures sustainable and reliable results
    • Principle  Turbidimetric immunoassay determination of urine albumin
    • Calibration                            Factory calibrated against a turbidimetric method with a calibrator traceable to

      CRM 470 (Certified Reference Material)

      Sample Material                  Urine; morning spot, overnight or 24 hour collections

       

      Measurement Range          5-150 mg/L

      Samples up to 2000 mg/L can be diluted with isotonic sodium chloride. Dilution

      might affect the precision of the results.

      Results                                   In 90 seconds

      Sample Volume                  18 μL

      Dimensions                          115 x 170 x 66 mm

      (4.53 x 6.89 x 2.56 inches)

      Weight                                   350 g (0.77 lbs)

      Storage Temp.                     Analyzer: 0-50 °C (32-122 °F)

      Microcuvettes: 2-8 °C (35-46 °F),

      room temperature for up to 3 days

      Operating Temp.                 15-30 °C (59-86 °F)

      Power                                    AC adapter

      Interface                                Printer and HemoCue® Basic Connect including barcode scanner

      Quality Control                     Built-in ”selftest”. System can be verified using liquid controls.